Using the Bluetooth connection with the PRIMES Cube, a convenient monitoring of the laser power with a mobile device like tablet or smartphone for AndroidTM is possible. Aside from the graphic display and backup of the measured values stored in the Cube, it is possible to define presets for measurement series and transfer them to the Cube using the Bluetooth connection.The readings laser power, pulse duration and energy per pulse can be displayed graphically on the mobile device. In addition, a standard deviation evaluation of the measured values is possible with the PRIMES Cube App.
The PRIMES Cube App is available in the Google Play Store as free download.

The absorber of the calorimetric measurement system is irradiated by a laser for a short period of time. The temperature difference of the absorber between start and finish of the laser pulse is measured. From the temperature rise, the microprocessor based electronics is able to calculate laser power to a high degree of accuracy. An interlock signal is provided in order to turn off the laser beam emission, should the absorber overheat. The usage of this signal is strongly recommended.

Ominaisuudet

The absorber of the calorimetric measurement system is irradiated by a laser for a short period of time. The temperature difference of the absorber between start and finish of the laser pulse is measured. From the temperature rise, the microprocessor based electronics is able to calculate laser power to a high degree of accuracy. An interlock signal is provided in order to turn off the laser beam emission, should the absorber overheat. The usage of this signal is strongly recommended.

Tekniset tiedot

The Cube measures the incident laser energy and the irradiation time. The calculated laser power has an accuracy of ± 3 %, with a repeatability of ± 1 %. The typical working temperature range of the Cube lies between +15 °C and +40 °C.

System parameters for the Laser:

  • Wavelength: 900 – 1090 nm
  • Power range: 25 – 12000 W (average power)
  • Measurement time = Pulse duration: 0.1 – 2 s

Laser power and irradiation time stand in direct relationship for the measurement.

Measuring very high power densities? No longer a problem: the new Cube M by PRIMES enables measurements up to a power density of 250 kW/cm² at a power of 2 kW!

The new model for your high power application: with the Cube L, you can easily measure the power of solid-state as well as fiber lasers up to 20 kW.